Task:
- Separation of hydrogen sulphide from the biogas produced by an agricultural biogas plant
- Installation and setup of the meter cabinet including all built-in components
- Fine tuning of air dosing
- Collaboration with project partners
System parameters:
- Pollutant concentration: 450 ppm of H₂S (average per day)
- Flow rate: 400 – 1100 Nm³ per hour
UGN Umwelttechnik solution:
- Process: BEKOM H 12.0
- Filtering material: 4 m³ of UgnCleanPellets® S3.5-13
8 m³ of UgnCleanPellets® S3.5-7
- Heating and flexible air dosing of the system