Bad Hersfeld | Biogas desulphurisation upstream of P2G system with complete H₂S removal

BEKOM 2.0 → design, construction, installation, filtering material, commissioning
Service Provider
Project
Location of performance / Site: Bad Hersfeld, Hesse, Germany, Europe
Date: 2013
Description

Task:

  • Separation of hydrogen sulphide from the biogas upstream of a P2G system
  • Desulphurisation target → 0 ppm of H₂S

System parameters:

  • Pollutant concentration: up to 200 ppm of H₂S
  • Flow rate: 100 Nm³ per hour

Solution:

  • UGN®-BEKOM 2.0 gas desulphurisation system
  • 4 m³ of UgnCleanPellets® S 3.5 filtering material BIO

Special features:

  • Less than 1 % vol. oxygen content in desulphurisation system
Gas Desulfurization Properties
Pollutant degradation: Hydrogen sulfide
Volume flow: 100 Nm³/h
Pollutant concentration: 200 ppm H2S
Filter material: UgnCleanPellets® S 3.5
Client