Chavornay, Switzerland | Biogas desulphurisation

Separation of hydrogen sulphide from the biogas produced by a composter, and reduction of CHP operating costs
Service Provider
Project
Location of performance / Site: Chavornay VD, Waadt, Switzerland, Europe
Period: Nov 2018 - Jul 2019
Description

Task:
Separation of hydrogen sulphide from the biogas produced by a composter, and reduction of CHP operating costs

System parameters:
Pollutant concentration: 100 … 300 ppm of H₂S on daily average

UGN Umwelttechnik solution:
Process: BEKOM H 6.0 (system made of stainless steel),
Filtering material: UgnCleanTubes® S3.5-13: 2 m³; UgnCleanPellets® S3.5-7: 4 m³

Gas Desulfurization Properties
Pollutant degradation: Hydrogen sulfide
Volume flow: 300 Nm³/h
Pollutant concentration: 300 ppm H2S
Filter material: UgnCleanPellets® S 3.5, UgnCleanTubes® S 3.5
Client
A company of the Energy and Water Supply industry from Baden, Schweiz