Task:
- Separation of hydrogen sulphide from the biogas produced by agricultural biogas plants
- Two identical plants
- Installation and setup of the meter cabinet and all built-in components
- Plant heating
- Air dosing provided by client
System parameters:
- Pollutant concentration: max. 100 ppm of H₂S
- Flow rate: 500 m³ per hour per plant
UGN Umwelttechnik solution:
- Process: 2× BEKOM H 5.0
- Filtering material: 4 m³ of UgnCleanTubes® S3.5-13
6 m³ of UgnCleanPellets® S3.5-7