| Location of performance / Site: | Werder (Havel), Brandenburg, Germany, Europe |
|---|---|
| Date: | 2017 |
Task:
Pollutants removed:
UGN® technology employed:
Project description:
The exhaust air from the mechanical wastewater treatment is fed into a central exhaust air filter with an upstream exhaust air humidifier by way of an air extractor. As a part of this project, UGN checked and readjusted the air extractor, converted the biofilter into a hybrid filter (by installing UgnCleanPellets S1.0) before recommissioning and redimensioning the system.
On top of that, the plastic air extractor was repaired and the humidifier and the fans were serviced.
| Pollutant degradation: | Ammonia (NH3), Organische Kohlenwasserstoffe (VOC), Hydrogen sulfide (H2S) |
|---|---|
| Volume flow: | 5,000 m³/h |
| Pollutant concentration (peak load): | 50 ppm H2S |
| Application area: | Exhaust air from wastewater treatment facilities |
| Filter material: | UgnCleanPellets® S 1.0 |